Updated Spectrum analyzer (markdown)
@@ -1,11 +1,11 @@
|
|||||||
|
# Sweep screen
|
||||||
Press `F` + `5 NOAA` to turn on spectrum analyzer.
|
Press `F` + `5 NOAA` to turn on spectrum analyzer.
|
||||||
|
|
||||||
The current VFO/Memory frequency is the **start frequency** of the spectrum sweep
|
The current VFO/Memory frequency is the **start frequency** of the spectrum sweep
|
||||||
|
|
||||||
|
|
||||||

|

|
||||||
|
|
||||||
# Button functions
|
## Button functions
|
||||||
* `1` / `7` - increase/decrease the channel separation of a single bar in the graph (typically 25.0 kHz)
|
* `1` / `7` - increase/decrease the channel separation of a single bar in the graph (typically 25.0 kHz)
|
||||||
* `4` - changes the number of channels to scan and toggles number of bars in the graph (typically 128x)
|
* `4` - changes the number of channels to scan and toggles number of bars in the graph (typically 128x)
|
||||||
* `2` / `8` - increase/decrease frequency step size for `UP/DOWN`
|
* `2` / `8` - increase/decrease frequency step size for `UP/DOWN`
|
||||||
@@ -19,7 +19,25 @@ The current VFO/Memory frequency is the **start frequency** of the spectrum swee
|
|||||||
* `EXIT` - exits to the previous screen/function
|
* `EXIT` - exits to the previous screen/function
|
||||||
* `PTT` - switch screen to _**detail monitoring**_ of last received frequency (_see below_)
|
* `PTT` - switch screen to _**detail monitoring**_ of last received frequency (_see below_)
|
||||||
|
|
||||||
|
.
|
||||||
|
# Detail Monitor screen
|
||||||

|

|
||||||
|
|
||||||
* `M` - Scrolls through the parameters displayed at the bottom of the screen which can be adjusted with `UP/DOWN`
|
* `M` - Scrolls through the parameters displayed at the bottom of the screen which can be adjusted with `UP/DOWN`
|
||||||
|
> LNA$ - Low Noise Amplifier $
|
||||||
|
>
|
||||||
|
> LNA - Low Noise Amplifier
|
||||||
|
>
|
||||||
|
> PGA - Programmable Gain Amplifier
|
||||||
|
>
|
||||||
|
> IF - Intermediate Frequency
|
||||||
|
|
||||||
* `EXIT` - exits to the previous screen of the spectrum analyzer
|
* `EXIT` - exits to the previous screen of the spectrum analyzer
|
||||||
|
|
||||||
|
.
|
||||||
|
# Documentation
|
||||||
|
* Instruction for the Spectrum Analyzer
|
||||||
|
[QuanSheng.UV.K5.Spectrum.analyzer.guide.EN.pdf](https://github.com/egzumer/uv-k5-firmware-custom/files/13242741/QuanSheng.UV.K5.Spectrum.analyzer.guide.EN.pdf)
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|||||||